SCHNEIDER - KONTAKTOR / CONTACTOR 3P 400A

Category: 3 POLE
No Referensi: LC1F400
HUBUNGI KAMI

Call / Whatsapp:


Whatsapp Only:


Tokopedia:

Main
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-3
AC-4
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current
500 A (<= 40 °C) at <= 440 V AC AC-1
400 A (<= 55 °C) at <= 440 V AC AC-3
motor power kW
75 kW at 400 V AC 50/60 Hz AC-4
200 kW at 380...400 V AC 50/60 Hz AC-3
220 kW at 415 V AC 50/60 Hz AC-3
250 kW at 440 V AC 50/60 Hz AC-3
257 kW at 500 V AC 50/60 Hz AC-3
185 kW at 1000 V AC 50/60 Hz AC-3
110 kW at 220...240 V AC 50/60 Hz AC-3
280 kW at 660...690 V AC 50/60 Hz AC-3
Complementary
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
500 A at <= 40 °C
Irms rated making capacity
4000 A AC conforming to IEC 60947-4-1
rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A <= 40 °C 10 s
2400 A <= 40 °C 30 s
1700 A <= 40 °C 1 min
1200 A <= 40 °C 3 min
1000 A <= 40 °C 10 min
associated fuse rating
400 A aM at <= 440 V
500 A gG at <= 440 V
average impedance
0.26 mOhm at 50 Hz - Ith 500 A
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole
42 W AC-3
65 W AC-1
mounting support
Plate
standards
EN 60947-1
EN 60947-4-1
IEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
product certifications
ABS
BV
CSA
DNV
LROS (Lloyds register of shipping)
RINA
RMRoS
UL
CB
connections - terminals
Power circuit : lugs-ring terminals 2 cable(s) 150 mm²
Power circuit : bar 2 x (30 x 5 mm)
tightening torque
Power circuit : 35 N.m
Environment
IP degree of protection
IP20 front face with shrouds (ordered separately) conforming to IEC 60529
IP20 front face with shrouds (ordered separately) conforming to VDE 0106
protective treatment
TH
ambient air temperature for operation
-5...55 °C
ambient air temperature for storage
-60...80 °C
permissible ambient air temperature around the device
-40...70 °C
operating altitude
3000 m without derating
mechanical robustness
Vibrations resistance contactor closed 5 Gn, 5...300 Hz
Vibrations resistance contactor open 1.5 Gn, 5...300 Hz
Shocks resistance contactor open 6 Gn for 1/2 sine wave (11 ms)
Shocks resistance contactor closed 15 Gn for 1/2 sine wave (11 ms)
height
206 mm
width
213 mm
depth
219 mm
product weight
8 kg