range of product | TeSys D |
---|---|
range | TeSys |
product or component type | Contactor |
device short name | LC1D |
contactor application | Motor control Resistive load |
utilisation category | AC-4 AC-2 AC-1 AC-3 |
control circuit type | AC at 50/60 Hz |
poles description | 3P |
pole contact composition | 3 NO |
[Ie] rated operational current | 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
motor power kW | 18.5 kW at 380...400 V AC 50 Hz 22 kW at 500 V AC 50 Hz 30 kW at 660...690 V AC 50 Hz 11 kW at 220...230 V AC 50 Hz 22 kW at 415 V AC 50 Hz 22 kW at 440 V AC 50 Hz 22 kW at 1000 V AC 50 Hz |
coil technology | Without built-in bidirectional peak limiting diode suppressor |
---|---|
Front cover | With |
motor power hp | 3 hp at 115 V AC 60 Hz for 1 phase motors 5 hp at 230/240 V AC 60 Hz for 1 phase motors 10 hp at 200/208 V AC 60 Hz for 3 phases motors 10 hp at 230/240 V AC 60 Hz for 3 phases motors 30 hp at 460/480 V AC 60 Hz for 3 phases motors 30 hp at 575/600 V AC 60 Hz for 3 phases motors |
auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
auxiliary contact composition | 1 NO + 1 NC |
[Uc] control circuit voltage | 42 V AC 50/60 Hz |
control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
[Ui] rated insulation voltage | Control circuit: 600 V CSA certified Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
overvoltage category | III |
mounting support | Plate Rail |
flame retardance | V1 conforming to UL 94 |
connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Power circuit: screw terminals 1 cable(s) 2.5…25 mm²rigid Power circuit: screw terminals 2 cable(s) 2.5…16 mm²rigid Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible without cable end Power circuit: screw terminals 2 cable(s) 2.5…16 mm²flexible without cable end Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible with cable end Power circuit: screw terminals 2 cable(s) 2.5…10 mm²flexible with cable end |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2 Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit 60 A (at 60 °C) for power circuit |
Irms rated making capacity | 800 A at 440 V for power circuit conforming to IEC 60947 140 A AC for control circuit conforming to IEC 60947-5-1 |
rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit |
power dissipation per pole | 5.4 W AC-1 2.4 W AC-3 |
inrush power in VA | 140 VA cos phi 0.75 (at 20 °C) 160 VA cos phi 0.75 (at 20 °C) |
hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
operating time | 4...19 ms opening 12...26 ms closing |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
mechanical durability | 6000000 cycles |
maximum operating rate | 3600 cyc/h 60 °C |
minimum switching current | 5 mA for control circuit |
minimum switching voltage | 17 V for control circuit |
non-overlap time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts |
insulation resistance | > 10 MOhm for control circuit |
height | 127 mm |
width | 75 mm |
depth | 119 mm |
net weight | 1.4 kg |