SCHNEIDER - NSX100N 50KA TM16D 3P

Category: NSX
No Referensi: LV429847
HUBUNGI KAMI

Call / Whatsapp:


Whatsapp Only:


Tokopedia:

Main
range
Compact
product name
Compact NSX
product or component type
Circuit breaker
device short name
Compact NSX100N
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
network frequency
50/60 Hz
[In] rated current
100 A ( 40 °C )
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ue] rated operational voltage
690 V AC 50/60 Hz
breaking capacity code
N (50 kA) AC
breaking capacity
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
50 kA at 480 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
[Ics] rated service breaking capacity
Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Ics 35 kA 525 V AC 50/60 Hz conforming to IEC 60947-2
Ics 36 kA 500 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
Ics 90 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit protection functions
LI
trip unit rating
16 A ( 40 °C )
protection type
Overload protection (thermal) L
Short-circuit protection (magnetic) I
pollution degree
3 conforming to IEC 60664-1
Complementary
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
auxiliary contact composition
Without
mechanical durability
50000 cycles
electrical durability
10000 cycles 690 V In conforming to IEC 60947-2
20000 cycles 690 V In/2 conforming to IEC 60947-2
30000 cycles 440 V In conforming to IEC 60947-2
50000 cycles 440 V In/2 conforming to IEC 60947-2
connection pitch
35 mm
local signalling
Positive contact indication
long time pick-up adjustment type Ir
Adjustable
long time pick-up adjustment range
0.7...1 x In
long time delay adjustment type
Fixed
[tr] long-time delay adjustment range
15 s 6 x Ir
120...400 s 1.5 x In
short-time pick-up adjustment type Isd
Fixed
[Isd] short-time pick-up adjustment range
190 A
short-time delay adjustment type
Fixed
height
161 mm
width
105 mm
depth
86 mm
product weight
2.05 kg
Environment
overvoltage category
Class II
electrical shock protection class
Class II
standards
EN/IEC 60947
UL 508
product certifications
CCC
Marine
EAC
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
ambient air temperature for operation
-35...70 °C
ambient air temperature for storage
-55...85 °C