SCHNEIDER - KONTAKTOR / CONTACTOR 115A 1NC+1NO 220V 50/60HZ

Category: 3 POLE
No Referensi: LC1D115M7
HUBUNGI KAMI

Call / Whatsapp:


Whatsapp Only:


Tokopedia:

Main
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-3
AC-4
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 300 V DC for power circuit
<= 1000 V AC 25...400 Hz for power circuit
[Ie] rated operational current
200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
115 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
motor power kW
55 kW at 380...400 V AC 50/60 Hz AC-3
75 kW at 500 V AC 50/60 Hz AC-3
80 kW at 660...690 V AC 50/60 Hz AC-3
30 kW at 220...230 V AC 50/60 Hz AC-3
59 kW at 415...440 V AC 50/60 Hz AC-3
65 kW at 1000 V AC 50/60 Hz AC-3
18.5 kW at 400 V AC 50/60 Hz AC-4
motor power HP (UL / CSA)
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
220 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
Conforming to IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
200 A at <= 60 °C for power circuit
Irms rated making capacity
1260 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
1100 A <= 40 °C 1 s power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
250 A <= 40 °C 10 min power circuit
550 A <= 40 °C 1 min power circuit
950 A <= 40 °C 10 s power circuit
associated fuse rating
200 A gG at <= 690 V coordination type 2 for power circuit
250 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for signalling circuit
average impedance
0.6 mOhm at 50 Hz - Ith 200 A for power circuit
[Ui] rated insulation voltage
1000 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
electrical durability
0.8 Mcycles 200 A AC-1 at Ue <= 440 V
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
power dissipation per pole
24 W AC-1
7.9 W AC-3
safety cover
With
mounting support
Plate
Rail
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
connections - terminals
Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end
Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end
Control circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
Control circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end
Control circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end
Power circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - without cable end
Power circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - without cable end
Power circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - with cable end
Power circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - with cable end
Power circuit : connector 1 cable(s) 10...120 mm² - cable stiffness: solid - without cable end
Power circuit : connector 2 cable(s) 10...50 mm² - cable stiffness: solid - without cable end
tightening torque
Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit : 12 N.m - on connector hexagonal 4 mm
operating time
6...20 ms opening
20...50 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
8 Mcycles
operating rate
2400 cyc/h at <= 60 °C
Complementary
coil technology
Built-in bidirectional peak limiting diode suppressor
control circuit voltage limits
0.3...0.5 Uc drop-out at 55 °C, AC 50/60 Hz
0.8...1.15 Uc operational at 55 °C, AC 50/60 Hz
inrush power in VA
280...350 VA at 20 °C (cos ϕ 0.8) 60 Hz
280...350 VA at 20 °C (cos ϕ 0.8) 50 Hz
hold-in power consumption in VA
2...18 VA at 20 °C (cos ϕ 0.3) 60 Hz
2...18 VA at 20 °C (cos ϕ 0.3) 50 Hz
heat dissipation
3...8 W at 50/60 Hz
auxiliary contacts type
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
non-overlap time
1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
insulation resistance
> 10 MOhm for signalling circuit
Environment
IP degree of protection
IP20 front face conforming to IEC 60529
protective treatment
TH conforming to IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5...60 °C
ambient air temperature for storage
-60...80 °C
permissible ambient air temperature around the device
-40...70 °C at Uc
operating altitude
3000 m without derating
fire resistance
850 °C conforming to IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz
Vibrations contactor closed 4 Gn, 5...300 Hz
Shocks contactor closed 15 Gn for 11 ms
Shocks contactor open 6 Gn for 11 ms
height
158 mm
width
120 mm
depth
136 mm
product weight
2.5 kg