SCHNEIDER - ATV340 1,5KW 2HP 400V WITH ETHERNET VARI

No Referensi: ATV340U15N4E
HUBUNGI KAMI

Call / Whatsapp:


Whatsapp Only:


Tokopedia:

Main
range of product
Altivar Machine ATV340
product or component type
Variable speed drive
product specific application
Machine
variant
Standard version
mounting mode
Cabinet mount
communication port protocol
Modbus serial
Ethernet/IP
Modbus TCP
option card
Communication module, Profibus DP V1
Communication module, Profinet
Communication module, DeviceNet
Communication module, CANopen
Communication module, EtherCAT
network number of phases
3 phases
supply frequency
50...60 Hz +/- 5 %
[Us] rated supply voltage
380...480 V - 15...10 %
nominal output current
4.0 A
motor power kW
2.2 kW for normal duty
1.5 kW for heavy duty
motor power hp
3 hp for normal duty
2 hp for heavy duty
EMC filter
Class C3 EMC filter integrated
IP degree of protection
IP20
Complementary
discrete input number
5
discrete input type
PTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm
programmable
number of preset speeds
16 preset speeds
discrete output number
2.0
discrete output type
Programmable output DQ1, DQ2 30 V DC 100 mA
analogue input number
2
analogue input type
AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
analogue output number
2
analogue output type
Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
relay output number
2
output voltage
<= power supply voltage
relay output type
Relay outputs R1A
Relay outputs R1C electrical durability 100000 cycles
Relay outputs R2A
Relay outputs R2C electrical durability 100000 cycles
maximum switching current
Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
minimum switching current
Relay output R1B: 5 mA at 24 V DC
Relay output R2C: 5 mA at 24 V DC
physical interface
2-wire RS 485
connector type
3 RJ45
method of access
Slave Modbus RTU
Slave Modbus TCP
transmission rate
4.8 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
transmission frame
RTU
number of addresses
1…247
data format
8 bits, configurable odd, even or no parity
type of polarization
No impedance
4 quadrant operation possible
True
asynchronous motor control profile
Constant torque standard
Optimized torque mode
Variable torque standard
synchronous motor control profile
Permanent magnet motor
Reluctance motor
pollution degree
2 conforming to EN/IEC 61800-5-1
maximum output frequency
0.599 kHz
acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s
S, U or customized
motor slip compensation
Adjustable
Not available in permanent magnet motor law
Can be suppressed
Automatic whatever the load
switching frequency
2...16 kHz adjustable
8...16 kHz with derating factor
nominal switching frequency
4 kHz
braking to standstill
By DC injection
brake chopper integrated
True
line current
5.1 A at 380 V (normal duty)
4.1 A at 480 V (normal duty)
6.0 A at 380 V (heavy duty)
4.9 A at 480 V (heavy duty)
line current
6 A at 380 V without line choke (heavy duty)
4.9 A at 480 V without line choke (heavy duty)
5.1 A at 380 V with external line choke (normal duty)
4.1 A at 480 V with external line choke (normal duty)
3.5 A at 380 V with external line choke (heavy duty)
2.8 A at 480 V with external line choke (heavy duty)
maximum input current
6.0 A
maximum output voltage
480 V
apparent power
3.8 kVA at 480 V (normal duty)
4.1 kVA at 480 V (heavy duty)
maximum transient current
6.2 A during 60 s (normal duty)
6 A during 60 s (heavy duty)
7.6 A during 2 s (normal duty)
7.2 A during 2 s (heavy duty)
electrical connection
Screw terminal, clamping capacity: 1.5...4 mm² for line side
Screw terminal, clamping capacity: 4...6 mm² for DC bus
Screw terminal, clamping capacity: 1.5...4 mm² for motor
Screw terminal, clamping capacity: 0.2...2.5 mm² for control
prospective line Isc
5 kA
base load current at high overload
4.0 A
base load current at low overload
5.6 A